What Is the Chimney Doing?
Name the material, brick, block or a framed chase, and the trouble you have noticed. A mason calls back to arrange the visit and the scope.
What the Eckert crew does on this job
A wood stove holds a fire behind a door, and it leaks when the parts that seal it wear out. We replace the door rope, baffle boards or plates, firebrick and ceramic glass, then go over the stovepipe joints and the hearth pad beneath the stove. Where the stove vents into a masonry chimney, we look at the thimble and the brick around it, because that joint is where heat and smoke escape.
A Stove Is Only as Good as Its Seals
Every well-made wood stove depends on one idea: the fire should only get the air you allow it. The door, the glass and the ash pan all close against woven seals, and the controls on the front meter how much air enters. Once those seals wear, air leaks in around them, the fire takes more than you meant to give it, the stove gets hard to turn down and wood disappears faster than it should. Owners usually notice a stove that roars on the lowest setting, a door that latches with no resistance, or a fire that will not hold overnight anymore. Replacing the door and glass seals is the most common repair we make on a stove, and it often restores control on its own. We test the result by closing the door on a strip of paper at several points around its edge; where the paper slides out freely, the seal is not doing its work.
Inside the stove, other parts wear on a slower clock. Firebrick panels lining the box protect the steel or cast iron from direct flame and crack in time; we replace them with bricks sized for the model. Baffle boards or plates at the top of the box take the full heat of the fire and warp, crack or shift out of place, and a baffle that has dropped changes how the stove burns and can let flame reach places it should not. On newer clean-burning stoves, the tubes that feed secondary air into the top of the box can burn through. Glass panels crack from heat shock and need ceramic glass cut to the model's size. We look for cracks in the stove body itself as well, particularly around the door frame and the flue collar, since a cracked casting changes the repair from parts to a decision about the stove.
The Masonry Around the Stove
Where a wood stove meets the house, the work becomes masonry. Many stoves in older Monterey Park homes stand in front of, or inside, a brick fireplace and connect to its flue. That connection is where we find the most faults. A stovepipe pushed loosely into a hole in the brick, without a proper thimble or a liner, leaves a gap through which smoke and heat reach the chimney walls. A stove venting into an old tile flue sized for an open fireplace often drafts poorly, cools its smoke and coats the flue with creosote faster than you would expect. A stainless pipe dropped down the old flue and joined to the stove collar cures both problems. We also check the hearth the stove stands on, since stoves need a non-combustible floor of a set size in front and to the sides, and many older hearths fall short or have cracked tiles that let heat through.
A repair visit starts with you describing how the stove behaves and how long ago it was installed. We inspect the stove inside and out, the pipe, the connection into the chimney, the flue and the hearth, then write a price that separates the stove repairs from the masonry and venting work so you can see each one. If the stove is very old and its body is cracked, or if parts for it are no longer made, we tell you plainly and give you the cost of a new stove or insert alongside the repair. Owners in Montebello, Bell Gardens and Los Angeles who burn wood should also know that the South Coast AQMD can call winter no-burn days, which matters when deciding how much to spend on a stove used only a few weeks a year. Get in touch with a short description and we will suggest the right visit.
How Eckert Chimney Company Works
Mix to Match
Mortar chosen for the age and hardness of the brick
Source First
Leaks and cracks traced to their cause before repair
Scope on Paper
Defect, material, method and price listed up front
Photos After
Finished joints and brick photographed for your file
Where our crews take on wood stove repair
Pick a city to read how its housing stock, brick and weather bear on the work.
CA
Monterey Park Wood Stove Repair
Hill streets here pair older brick with fireplaces added years later, so one roofline can hold two kinds of mortar. Pre-1980 stock runs to 79%. We test which mix sits in the joint before any tuckpointing starts.
Read the local notesCA
Montebello Wood Stove Repair
Brick laid before 1950 accounts for 23% of homes, and 84% came before 1980. Old lime-set joints like those get raked by hand and refilled with a soft mix, never a hard Portland patch that spalls the brick face.
Read the local notesCA
Los Angeles Wood Stove Repair
Craftsman and Spanish Revival streets sit inside Historic Preservation Overlay Zones, where a chimney repair must pass as original. We source brick by size and color and copy the old joint tooling. Owners hold just 36% of homes.
Read the local notesCA
Bell Gardens Wood Stove Repair
Families settled this farmland in small houses, and in the 1930s many arrived from the Dust Bowl. A block stack hiding behind gas logs still needs full grout and tight head joints, so we relay it with matching block.
Read the local notesMore Trade Work From Eckert
Chimney Sweep
Creosote brushed off the flue walls, then the firebox brick and joints read while they are bare and clean.
Open this job →Chimney Inspection
A mason's read of the stack, crown, flue tile and firebox under the NFPA 211 levels, written up with photos.
Open this job →Chimney Repair
Open joints, split crowns, broken flue tile and loose brick put right with mortar and materials matched to the chimney.
Open this job →Fireplace Inspection
Firebox brick, mortar, hearth slab, lintel and damper read from inside the room, each defect named and photographed.
Open this job →Fireplace Repair
Firebrick relaid in refractory mortar, hearths reset, lintels and dampers fixed, so the firebox holds heat as built.
Open this job →Chimney Level 2 Inspection
A recorded camera pass up every foot of flue tile, with seams and mortar voids logged, to NFPA 211 Level 2.
Open this job →Chimney Cap Installation
Stainless or copper caps set on a sound crown and fastened down, so Santa Ana winds cannot lift them off.
Open this job →Chimney Flashing Repair
Step and counter flashing let into the mortar joints, so the seam where brick meets roofing sheds water again.
Open this job →Chimney Masonry Repair
Tuckpointing, brick replacement and spall repair, with mortar and brick matched to the chimney in strength, color and size.
Open this job →Chimney Rebuilds
Stacks relaid from the roofline or from the firebox up, in matched brick, with new tile or liner and a cast crown.
Open this job →Fireplace Cleaning
Firebox, smoke shelf, glass and the brick face around the opening cleaned of soot and ash, gently enough for old brick.
Open this job →Gas Fireplace Cleaning
Ports, pilot hood, ember material, logs and glass on a gas unit cleaned, then the flame and vent looked over.
Open this job →Gas Fireplace Repair
Thermocouples, thermopiles, valves and igniters on gas fireplaces tested and replaced, with fittings and vent looked over.
Open this job →Fireplace Remodel
Hearths rebuilt and fireplace faces relaid in brick, stone or tile, set to code clearances and the style of the house.
Open this job →Fireplace Inserts
Gas or wood inserts set into an existing masonry firebox, with a stainless liner up the flue and the opening trimmed tight.
Open this job →Pellet Stove Repair
Augers, igniters, blowers and control boards on pellet stoves diagnosed and fixed, with the exhaust pipe cleaned out.
Open this job →Gas Logs
Gas log sets fitted to a masonry firebox, burner and logs matched to the opening and the flue kept clear to vent.
Open this job →Chimney Seismic Retrofit
Older brick stacks braced, strapped or rebuilt lighter above the roof, with the masonry repaired before any steel goes on.
Open this job →Chimney Crown Repair
Cracked or thin chimney crowns sealed, patched or cast new with a projecting edge and a bond break around the tile.
Open this job →Dryer Vent Cleaning
Lint packed in dryer ducts cleared from the wall hood back to the machine, with crushed or long runs pointed out.
Open this job →Chimney Liner Installation
Stainless or cast liners fitted into cracked or unlined flues, sized to the appliance and sealed where they meet the brick.
Open this job →Chimney Leak Repair
Water traced to the crown, flashing, cap or brick face, and the real source repaired instead of caulked over.
Open this job →Chimney Waterproofing
A breathable silane or siloxane repellent applied to repaired brick, so it sheds rain but still dries out.
Open this job →Chimney Damper Repair
Throat dampers freed, replated or reset in mortar, or swapped for a lid-style damper on top of the flue.
Open this job →Chimney Chase Cover
Rusted or sagging chase tops on framed chimneys replaced with a stainless or galvanized cover cut to the chase.
Open this job →